4,900 €
Make an offer| Manufacturer | Agilent |
|---|---|
| Model | AriaDx Real Time PCR K8930AA |
| Year | 2021 |
| Location | France
|
| Category | Laboratory - General laboratory equipment |
| Product id | P260427317 |
| Language |
| ------------------- | |
| Length x width x height | 500.0 × 460.0 × 420.0 |
| Weight | 25 kg |
| worked hours | |
| hours under power | |
| state | excellent |
| At local norms | yes |
| status | visible |
| Last availability date | 28/04/2026 |
Agilent AriaDx Real Time PCR Thermocycler K8930AA
Year of manufacture: 2021
Model: K8930AA
With computer (ARIADX software installed)
Without cables
Excitation source: 8 LEDs specific to each dye per optical module
Detectors: 8 photodiodes
Reaction volume: 10 to 30 µl
Compatible chemistries: SYBR and TaqMan
Thermal system: 6 Peltier modules (25.0 to 99.9 °C)
Heating rate: 6.0 °C/s
Cooling rate: 2.5 to 3.0 °C/s
Thermal accuracy: ± 0.2 °C
Thermal uniformity: ± 0.4 °C
Data acquisition time: < 3 seconds for all channels
Power supply: 100-240 V AC, 50/60 Hz Frequency: 1100 Hz
Dimensions: 50 cm (L) x 46 cm (D) x 42 cm (H)
Weight: 23 kg
Sample containers: 96-well plates, strip tubes, 0.2 ml tubes
Operating conditions: 20 – 30 °C, relative humidity: 20 – 80 % (non-condensing)
The device is fully functional, but intervention by an AGILENT technician is required for recommissioning.
An internal test has been performed; everything is in order except the following error message: « Block contamination error ».
Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase
| Client type | Machinery dealer |
| Active since | 2018 |
| Offers online | 97 |
| Last activity | May 6, 2026 |
Agilent AriaDx Real Time PCR Thermocycler K8930AA
Year of manufacture: 2021
Model: K8930AA
With computer (ARIADX software installed)
Without cables
Excitation source: 8 LEDs specific to each dye per optical module
Detectors: 8 photodiodes
Reaction volume: 10 to 30 µl
Compatible chemistries: SYBR and TaqMan
Thermal system: 6 Peltier modules (25.0 to 99.9 °C)
Heating rate: 6.0 °C/s
Cooling rate: 2.5 to 3.0 °C/s
Thermal accuracy: ± 0.2 °C
Thermal uniformity: ± 0.4 °C
Data acquisition time: < 3 seconds for all channels
Power supply: 100-240 V AC, 50/60 Hz Frequency: 1100 Hz
Dimensions: 50 cm (L) x 46 cm (D) x 42 cm (H)
Weight: 23 kg
Sample containers: 96-well plates, strip tubes, 0.2 ml tubes
Operating conditions: 20 – 30 °C, relative humidity: 20 – 80 % (non-condensing)
The device is fully functional, but intervention by an AGILENT technician is required for recommissioning.
An internal test has been performed; everything is in order except the following error message: « Block contamination error ».
Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase
| ------------------- | |
| Length x width x height | 500.0 × 460.0 × 420.0 |
| Weight | 25 kg |
| worked hours | |
| hours under power | |
| state | excellent |
| At local norms | yes |
| status | visible |
| Last availability date | 28/04/2026 |
| Client type | Machinery dealer |
| Active since | 2018 |
| Offers online | 97 |
| Last activity | May 6, 2026 |